Supports all VME modules supported by Series 90-70.
Supports RX7i data monitoring over the web. Allows a combined total of up to 16 web server
and FTP connections.
INQUIRE NOW
Products Name: 6VAF343010B-A2 GE Input module Brand new
PRODUCT DESCRIPTION
Brand:GE
Model number:6VAF343010B-A2
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.27kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
6VAF343010B-A2 GE Input module Brand new
PCM (to CPU) communications
timeout
The PCM has a default backplane communications timeout value of 5
seconds. After the PCM has sent a request to the CPU, the PCM
applies this timeout while waiting on a response back from the CPU. In
most cases, the CPU will respond well within the 5–second timeout;
however, in certain instances the CPU can take longer than 5 seconds
to respond. These cases are limited to LOADs or STOREs of program
and/or configuration -especially if blocks in the program are larger than
8 KBytes. Folders containing EXE blocks (again with *.EXE files >8
KBytes) are most likely to cause problems. To ensure that the PCMs
do not observe backplane timeouts, a file must be loaded (using termf)
to the PCM. The file must be a binary file named CPU.ENV. The
contents of this file are as below (all values are specified in
hexadecimal):
Once the binary file CPU.ENV (below) is created, use termf to load
CPU.ENV to the PCM. Then execute a soft reset of the PCM. After
executing the soft reset, the PCM’s backplane communications
timeout should be 10 seconds.
Note: A copy of the above CPU.ENV file can be obtained from
http://www.ge-ip.com/support.
CAUTION
The CPU.ENV file will not be used when a hard reset is performed
on the PCM. With the CPU.ENV file resident in the PCM, a soft
reset must be performed after every hard reset of the PCM. Be
aware that it is possible to issue a soft reset COMMREQ from the
Ladder Diagram application; therefore, the application can be
modified to handle the required reset of PCMs after a power cycle
of the controller system.
Discrete Input
Modules(1) IC200MDL140 Input 120 VAC (1 Group of 8) 8
Points IC200MDL631 Input 125 VDC Pos/Neg Logic
Isolated 8 Points
IC200MDL141 Input 240 VAC (1 Group of 8) 8
Points IC200MDL632 Input 125 VDC Pos/Neg Logic
Isolated 16 Points
IC200MDL143 Input 120 VAC Isolated 8 Points IC200MDL635 Input 48 VDC Pos/Neg Logic (2
Groups of 8) 16 Points
IC200MDL144 Input 240 VAC Isolated 4 Points IC200MDL636 Input 48 VDC Pos/Neg Logic (4
Groups of 8) 32 Points
IC200MDL240 Input 120 VAC (2 Groups of 8) 16
Points IC200MDL640 Input 24 VDC Pos/Neg Logic (2
Groups of 8) 16 Points
IC200MDL241 Input 240 VAC (2 Groups of 8) 16
Points IC200MDL643 Input 5/12 VDC Pos/Neg Logic (2
Groups of 8) 16 Points
IC200MDL243 Input 120 VAC Isolated 16 Points IC200MDL644 Input 5/12 VDC Pos/Neg Logic (4
Groups of 8) 32 Points
IC200MDL244 Input 240 VAC Isolated 8 Points IC200MDL650 Input 24 VDC Pos/Neg Logic (4
Groups of 8) 32 Points